-ca -cnlz -smat -wlu |
-dvexta=32 |
-crv |
-cko |
-m1 |
-cudc |
-b |
-s78c |
-sevc |
01 group1. 03 data-item1 pic x(10). 03 data-item2 pic 9(3). 78 group1-sz value length of group1. |
ACUCOBOL-GT option | isCOBOL solution |
---|---|
--noTrunc | Use -dznt |
--truncANSI | Use -dzta |
-a | Default behavior using isCOBOL |
-Ca | Use -vansi |
-Cb | Default behavior using isCOBOL |
-Ce | The same option is available in isCOBOL. Use -ce=extensions compiler option |
-Ci | Use -ci -dcd. Add iscobol.gui.screen_col_plus_base=0 to the configuration |
-Ck | Default behavior using isCOBOL |
-Cm | Not available in isCOBOL. isCOBOL has an option named -cm, but it’s for other purposes |
-Cp | Default behavior using isCOBOL |
-Cr | Use -crlk and -va compiler options. Set iscobol.gui.screen_col_zero=true in the configuration. |
-Cv | The same option is available in isCOBOL. Use -cv compiler option |
-D1 | The same option is available in isCOBOL. Use -d1 compiler option |
-D5 | The same option is available in isCOBOL. Use -d5 compiler option |
-D6 | Add the following entry to the configuration file: iscobol.compiler.regexp="(?i)(pic\\s+9\\([0-9]+\\)\\s+)(packed-decimal)" "$1 comp-6" |
-Da# | Use -align=# |
-Dca | The same option is available in isCOBOL. Use -dca compiler option |
-Dcb | The same option is available in isCOBOL. Use -dcb compiler option |
-Dci | The same option is available in isCOBOL. Use -dci compiler option |
-Dcm | The same option is available in isCOBOL. Use -dcm compiler option |
-Dcn | The same option is available in isCOBOL. Use -dcn compiler option |
-Dcr | The same option is available in isCOBOL. Use -dcr compiler option |
-Dd31 | Default behavior using isCOBOL. In order to have the same precision on the last decimal digits, use -cfp36 compiler option |
-Df | Use -cv compiler option |
-Di | Use -dia compiler option |
-Dm | Use -dcdm compiler option |
-Ds | The same option is available in isCOBOL. Use -ds compiler option |
-Dv=# | Use -dv=# and -dvexta=# compiler options |
-Dw32 | Default behavior using isCOBOL. |
-Dw64 | Use -d64 compiler option. Note that only USAGE POINTER data items are affected. |
-Dz | The same option is available in isCOBOL. Use -dz compiler option |
-e | Use -eo=folder compiler option. isCOBOL allows to specify the destination folder for error files, but not the file name. Files are always named ProgramName.err |
-Fa | Use -efa compiler option. isCOBOL generates dictionaries in XML format. Acucobol-GT’s XFD and isCOBOL XML are not compatible |
-Fm | The same option is available in isCOBOL. Use -fm compiler option |
-Fo | Use -efo=folder compiler option |
-Fx | Use -efd compiler option. isCOBOL generates dictionaries in XML format. Acucobol-GT’s XFD and isCOBOL XML are not compatible |
-Ga | Use either -d or -dx compiler options |
-Lf | The same option is available in isCOBOL, but isCOBOL list files are not in ANSI format by default. Use -lf and -la compiler options combined |
-Lo | Use -lo=folder compiler option. isCOBOL allows to specify the destination folder for list files, but not the file name. Files are always named ProgramName.list |
-Ls | Use -ld compiler option |
-o | Use -od=folder compiler option. isCOBOL allows to specify the destination folder for object files, but not the file name. Files are always named PROGRAMNAME.class |
-Rc | The same option is available in isCOBOL. Use -rc=word1,word2 compiler option |
-Rw | The same option is available in isCOBOL, but the usage is slightly different. In isCOBOL the option can’t be repeated, so all the reserved words must be specified at once separated by comma. E.g. the following Acu options: -rw word1 -rw word2 are translated to isCOBOL as follows: -rw=word1,word2 |
-S# (where # is the number of columns for each tab) | Use -stl=# compiler option |
-Sa | The same option is available in isCOBOL. Use -sa compiler option and avoid using -smat |
-Si | Add IF Directive to the source |
-Sl | The same option is available in isCOBOL. Use -sl compiler option. |
-Sp | The same option is available in isCOBOL. Use -sp=folders compiler option |
-Sr | Use -stl=8,4 |
-St | The same option is available in isCOBOL. Use -st compiler option and avoid using -smat |
-Sx | Add IF Directive to the source |
-v | The same option is available in isCOBOL. Use -v compiler option |
-Va | Not available in isCOBOL. isCOBOL has an option named -va, but it’s for other purposes |
-Vc | Default behavior using isCOBOL |
-Vh | The same option is available in isCOBOL. Use -vh compiler option |
-Vl | Default behavior using isCOBOL, unless -vh is used |
-Vu | The same option is available in isCOBOL. Use -vu compiler option |
-Vx | The same option is available in isCOBOL. Use -vx compiler option |
-Za | Set iscobol.array_check=1 and iscobol.substring_check=1 in the configuration |
-Zd | Use either -d or -dx compiler options |
-Zi | The same option is available in isCOBOL. Use -zi compiler option |
-Zo | Use -efo=folder compiler option |
-Zr# | Use either -pt0, pt1 or -pt2 compiler options according to your needs |
-Zx | Use -efd compiler option. isCOBOL generates dictionaries in XML format. Acucobol-GT’s XFD and isCOBOL XML are not compatible |
-Zy | The same option is available in isCOBOL. Use -zy compiler option |
-Zz | Default behavior in isCOBOL |